CARTRIDGE VALVE รุ่น LFA..EKWB

2-way cartridge valves with spool position monitoring รุ่น LFA..EKWB (control cover)

Cartridge Valve รุ่น  LFA EKWB
Cartridge Valves รุ่น LFA..EKWB (control cover)

รายละเอียด Cartridge Valves รุ่น LFA..EKWB (control cover)

  • Size 16...160
  • Component series 7X
  • Maximum operating pressure 420 bar
  • Maximum flow 25000 l/min

Features

  • Functional product design
  • Modular set-up:
    • Cartridge valve with various options
    • Control cover in various variants for realization of selected functions
    • Electronic monitoring of the spool position
  • Power and flow-optimized design:
    • High flows
    • Low pressure drops
    • High switching velocities
    • Low leakage oil flows
  • Robust design:
    • High reliability
    • Long life cycle
  • Other features:
    • Small installation size, low weight
    • Easy to service

Type code

010203 04 050607080910111213
LFA   EKWB 7X /     D Q..G24          

Type
01 Control cover LFA LFA
Size
02 NG 16 16
NG 25 25
NG 32 32
NG 40 40
NG 50 50
NG 63 63
NG 80 1) 80
NG 100 1) 100
NG 125 1) 125
NG 160 1) 160
Version
03 Control cover version "EKWB" With electrical control of the closed position for set-up of a directional spool or seat valve, with installed shuttle valve, incl. installation kit EKWB
Component series
04 Component series 70 to 79 (70 to 79: unchanged installation and connection dimensions) 7X
Spool design
05 A1 : A2 = 2 : 1 (annulus area = 50 %; standard version) CA
A1 : A2 = 14.3 : 1 (annulus area = 7 %) CB
Cracking pressure
06 Cracking pressure 1.0 bar 10
Cracking pressure 2.0 bar 20
Cracking pressure 4.0 bar 40
Damping
07 Valve poppet with damping nose D
Spool position monitoring
08 Electrical (NG 16…32) QMG24
Electrical (NG 40...63) Q6G24
Nozzle fitting
09 Orifice in channel B 2) B..
10 Orifice in channel P 2) P..
11 Orifice in channel T 2) 3) T..
Seal material
12 NBR seals no code
FKM seals V
Ports, plug screws and orifices
13 Metric no code
UNC /12

Version
CACB
LFA E CA  LFA E CB

Orifice symbolSymbol in ordering code 
A** LFA E A A** This orifice is designed as screw-type orifice. If an orifice is to be installed, the respective code letter with the orifice Ø in 1/10 mm has to be entered in the type designation. Example: A12 = Orifice with Ø1.2 mm in channel A.
Ø1,2 LFA E 01 2   This orifice is designed as bore. No specifications are made in the type designation. (Orifice Ø in mm)
Z12 LFA E Z12   This orifice is designed as screw-type orifice. This is a standard orifice. No specifications are made in the type designation. (Orifice Ø in 1/10 mm)

Pilot control valve (separate order)
Control coverPilot control valve
SizeVersionSizeDescription
16 … 50 EKWB 6 4/3-, 4/2-, 3/2-directional spool valve, direct operated (subplate mounting)
2/2-, 3/2-, 4/2 directional seat valve, direct operated (subplate mounting)
63...100 EKWB 10
125 EKWB 10
160 EKWB 25

ModelCode