Design |
01 |
Return line filter 25 bar |
25TE |
Size |
02 |
TE... (Filter elements according to Bosch Rexroth standard) |
0101 |
0201 |
0351 |
1051 |
Component series |
03 |
Component series 20 … 29 (20 … 29: unchanged installation and connection dimensions) |
2X |
Filter rating in μm |
04 |
Absolute (ISO 16889; βx(c)≥ 200) |
Non-woven glass fiber media, not cleanable |
H3XL |
H6XL |
PWR10 |
H20XL |
Water-absorbing, not cleanable |
AS6 |
AS10 |
AS20 |
Nominal |
Paper, not cleanable |
P10 |
P25 |
Stainless steel wire mesh, cleanable |
G10 |
G25 |
G40 |
G60 |
G100 |
Pressure differential |
05 |
Max. admissible pressure differential of the filter element 20 bar (with bypass valve) |
E00 |
Maintenance indicator | (1 unit per filter side) |
06 |
Without maintenance indicator |
Bypass cracking pressure 3,0 bar |
0 |
Back pressure switch, optical, switching pressure 2,2 bar 1) |
Bypass cracking pressure 3,0 bar |
A2,2 |
Back pressure switch, electrical, or optical-electrical, switching pressure 2,2 bar 2) |
Bypass cracking pressure 3,0 bar |
B2,2 |
Back pressure switch, electrical, ATEX, switching pressure 2,2 bar |
Bypass cracking pressure 3,0 bar |
F2,2 |
Seal |
07 |
NBR |
M |
FKM |
V |
Port |
08 |
|
Frame size |
0101 |
0201 |
0351 |
1051 |
|
Port |
|
|
|
|
|
|
G 1 |
|
● |
|
|
|
R4 |
G 1 1/2 |
|
|
● |
|
|
R6 |
SAE 2" – 3000 psi |
|
|
|
● |
|
S8 |
SAE 3" - 3000 psi |
|
|
|
|
● |
S10 |
● = Standard |
Supplementary information |
(multiple specifications possible) |
09 |
Threaded coupling for venting, only if used as an inline filter, instead of a maintenance indicator |
M |
Without bypass valve |
NB |
Manufacturer's inspection certificate M according to DIN 55350 T18 |
Z1 |